When I connect the MCS6/MPA4(T) to a Windows 7 PC, the PC somehow doesn't ask or install its driver. Isn't the MCS6 also working on Windows 7?
Category: Ultra Fast Multiscalers, Multiparameter Multichannel AnalyzersWhat advantages would the MPA4 provide, relative to the MPA-3?
Category: Multiparameter Multichannel AnalyzersIs it possible with the MPA-3 to get time spectra individually say for ADC1 (T1) and ADC2 (T2) ? Is it possible to get a time spectra for the difference (TI - T2)? Is there any common reference of time for all ADC inputs?
Category: Multiparameter Multichannel AnalyzersIt doesn't work with Combined conditions on 2 different ADC (ROI1 of ADC1A "OR" ROI1 of ADC2A), Why ?
Category: Multiparameter Multichannel AnalyzersI would like to use the MPA-3 for building a spectra containing the sum of the counts from several smaller detectors to get a "superdetector". Is that possible?
Category: Multiparameter Multichannel AnalyzersShe is not getting time spectra using RTC option. The AUX input was not used. Is it not possible to get time spectra with RTC option without using AUX input? She opted for software start but no spectra came.
Category: Multiparameter Multichannel AnalyzersIt's possible to control the MPA server by sending commands over a TCP/IP net ? - what are the messages to send : can we do all the functions available in the DLL?
Category: Multiparameter Multichannel AnalyzersIs it possible to inspect MPA-3 datafiles under Linux (offline, without connected hardware) (MPANT seems not to run under wine)?
Category: Multiparameter Multichannel AnalyzersWhen using the logsums command we noticed that the logfile does not update until we exit out of the program or the logfile name is changed. Is there any way to get the sums to automatically be saved into a .txt file after we have replayed the data?
Category: Multiparameter Multichannel AnalyzersIs it possible to read "on line" all the events with an external application written in VB.NET or Labview or C++ ... ?
Category: Multiparameter Multichannel Analyzers, DLL SoftwareIs it possible to do time-of-flight measurements using MPA-3 with RTC by acquiring an ADC spectra for a time window and starting the time by a chopper signal?
Category: Multiparameter Multichannel AnalyzersI use fast position-dependent detectors with delay-line read out. The maximum count rate that I can reach using two 7072T TDC's in coincidence and MPA-3 is only about 350 kHz per input. Is there a solution that can handle a higher count rate?
Category: Ultra Fast Multiscalers, Multiparameter Multichannel Analyzers, NIM-ModulesOn what conditions in the ADC/ MPA-3 can result in counts (especially large numbers of counts) appearing in MPA-3 channel 0. The customer is experiencing this. How can he eliminate it?
Category: Multiparameter Multichannel AnalyzersAbout the 4K and 16K FIFO: Can you give me some firm ideas on how to recommend to customers which they need?
Category: Multiparameter Multichannel Analyzers
