INPUTS and OUTPUTS External Trigger: 1 V positive pulse triggers a pulse (single or double), with internal delay and width controls operative. 50 Ohms input impedance, +/- 5 V maximum input. Drive: 1 V positive pulse generates an output pulse with a width equal to the width of the incoming pulse, internal delay and width controls are operative. 50 Ohms input impedance, +/- 5 V maximum input. Internal / External Reference: With Internal Reference, the output pulse amplitude is controlled only by the Amplitude and Normalize controls. With External Reference, an applied positive level controls the output pulse amplitude. Input: +5 V max, 5 k input impedance. Output Amplitude: Flat Top: 0.0 V to 2 V into 50 Ohms, 0.0 V to 4 V into high impedance, continuously adjustable with ten-turn potentiometer. 50 Ohm source impedance. Tail Pulse: 0.0 V to 1.5 V into 50 Ohms, 0.0 V to 3 V into high impedance, continuously adjustable with ten-turn potentiometer. 50 Ohm source impedance. Polarity: Simultaneous positive and negative pulses are available. Trigger Out: Positive 3 V pulse, 10 ns rise time, 50 Ohms output impedance. GENERAL Amplitude Characteristics: Temperature stability: less than 1% variation from 0-50 oC. Duty cycle variations: Less than 1%up to 90% duty factor. Linearity: less than 1% integral nonlinearity. Power Requirements: +12V at 500 mA, -12V 400 mA, +6V at 80 mA, -6 V at 425 mA. | CONTROLS Single cycle: One pulse occurs each time the push button is depressed. Normalize: Multi-turn potentiometer will vary the amplitude up to 50%. Rise Time (10-90%): Tail Pulse: 3 ns to 250 ns in six steps. Flat Top: 4 ns to 250 ns in six steps. Decay Time Constant (100-37%): 5 ns to 10 µs in eight steps. Frequency: A: 10 Hz to 50 MHz, continuously adjustable with coarse and fine controls. B: External trigger, 0 Hz to 50 MHz Delay: 10 ns - 10 ms, continuously adjustable with coarse and fine controls. Width: 5 ns - 5 ms, continuously adjustable with coarse and fine controls. Flat Top / Tail Pulse: Toggle switch selects the output pulse shape. The width controls are functional only in the flat top mode. Single/Double Pulse: In the single-pulse mode, a single output pulse occurs which is delayed from the Trigger Out by an amount determined by the Delay controls. In the double-pulse mode, two equal-width out pulses occur. The first pulse is simultaneous with the Trigger Out. Pulse separation set by delay controls. PHYSICAL Size: Triple width NIM module 4.05" wide x 8,70" high in accordance with TID-20893 (Rev. 3). Weight: 4.5 lbs. (2 kg) net; 7lbs. (3.2 kg) shipping. |